Running:
s10u4_b12b + patches
sc32_ga + patches
vxvm 5.0 + patches
ha-informix from /workspace/neilga/ohacds+5.10+sparc
IDS from dv5.sfbay:/swlib/ibm/released/informix/11/11.10/sparc-sunos
Problem:
I configured informix on failover zone and all resources came online fine on zone where I installed informix. Later I switched to backup node and informix was not comming online so I went to try the start command in the local zone as root which created /var/tmp/idsdb_logfile as root and because of this the rs went to and remained online:online eventhough the db was not started. This problem only occurs in failover zones. See comments for email thread w/ Neil on this problem.