Synopsis Appliance\Share becomes unbrowseable for ~10 mins after CIFS client leaves/rejoins the workgroup
State 10-Fix Delivered (Fix available in build)
Category:Subcategory utility:cifs
Keywords
Responsible Engineer Alan M Wright
Reported Against fw_23
Duplicate Of
Introduced In solaris_nevada
Commit to Fix snv_106
Fixed In snv_106
Release Fixed solaris_nevada(snv_106)
Related Bugs 6731101 , 6736548 , 6764225 , 6764343 , 6765259
Submit Date 10-March-2008
Last Update Date 16-January-2009
Description
Appliance Name	x4500-04a
Appliance Type	nas 1.0
First Installed at	Thursday, March 06, 2008 1:24:07 PM
Last Updated at	Thursday, March 06, 2008 1:24:07 PM
Last Booted at	Thursday, March 06, 2008 1:27:03 PM
Appliance Serial Number	60665ecb-5732-4f78-90ad-a38d4a4cbea1
Chassis Serial Number	00:14:4F:20:FD:E0
Appliance Part Number	Sun Microsystems, Inc. 000-0000
Appliance Product ID	urn:unknown
Browser Name	Netscape 5.0 (Windows; en-US)
Browser Details	Mozilla/5.0 (Windows; U; Windows NT 6.0; en-US; rv:1.8.1.12) Gecko/20080201 Firefox/2.0.0.12
HTTP Server	Apache/2.2.6 (Unix)
SSL Version	OpenSSL 0.9.8a 11 Oct 2005 (+ security patches to 2007-10-13)
Appliance Kit	Fishworks Appliance Kit 1.0 fw_23 2008-03-05
Operating System	SunOS 5.11 fw_23
BIOS	American Megatrends Inc. 080010 08/04/2006
Hardware	Sun Fire X4500
Service Processor	1.0
------------------------------------------------------------------------------
Description:
After performing the following steps, the appliance is no longer listed as a member of the workgroup that it, as well as the CIFS client, were previously members of for around 10 mins. 

- Join the CIFS client to a workgroup shared with the appliance. Browse to a shared filesystem. Mount and write to it.
- Leave the workgroup, join another workgroup and rebooting the client. Verify you cannot see the appliance or its resources.
- Rejoin the workgroup shared with the appliance from a CIFS client, reboot the client.
 
At this point, the appliance is no longer listed as a member of the workgroup in Windows Explorer when I attempt to browse and find it. Net view also does not show the appliance. 

If I manually map the share (using the tools, map network drive drop down menu option) I am prompted for the local user login for the appliance. I log in, mapping the resource. The appliance still does not appear in the workgroup list in Windows explorer. (I attempted to refresh windows explorere many times without success)

Eventually after around 10 mins, an "unknown" entry appears in the workgroup, as well as the appliance name itself. After selecting either one, you are prompted for the appliance local user account login. You are once again able to browse the appliance resources from Windows explorer.
Work Around
You can manually map a filesystem from the "Tools" menu of windows explorer at any time. 
After approximately 10 minutes, the appliance appears in windows explorer workgroup.
Each time you join a new workgroup, refresh the SMB SMF service.
Comments