Description
|
Appliance Name x4500-04a
Appliance Type nas 1.0
First Installed at Thursday, March 06, 2008 1:24:07 PM
Last Updated at Thursday, March 06, 2008 1:24:07 PM
Last Booted at Thursday, March 06, 2008 1:27:03 PM
Appliance Serial Number 60665ecb-5732-4f78-90ad-a38d4a4cbea1
Chassis Serial Number 00:14:4F:20:FD:E0
Appliance Part Number Sun Microsystems, Inc. 000-0000
Appliance Product ID urn:unknown
Browser Name Netscape 5.0 (Windows; en-US)
Browser Details Mozilla/5.0 (Windows; U; Windows NT 6.0; en-US; rv:1.8.1.12) Gecko/20080201 Firefox/2.0.0.12
HTTP Server Apache/2.2.6 (Unix)
SSL Version OpenSSL 0.9.8a 11 Oct 2005 (+ security patches to 2007-10-13)
Appliance Kit Fishworks Appliance Kit 1.0 fw_23 2008-03-05
Operating System SunOS 5.11 fw_23
BIOS American Megatrends Inc. 080010 08/04/2006
Hardware Sun Fire X4500
Service Processor 1.0
------------------------------------------------------------------------------
Description:
After performing the following steps, the appliance is no longer listed as a member of the workgroup that it, as well as the CIFS client, were previously members of for around 10 mins.
- Join the CIFS client to a workgroup shared with the appliance. Browse to a shared filesystem. Mount and write to it.
- Leave the workgroup, join another workgroup and rebooting the client. Verify you cannot see the appliance or its resources.
- Rejoin the workgroup shared with the appliance from a CIFS client, reboot the client.
At this point, the appliance is no longer listed as a member of the workgroup in Windows Explorer when I attempt to browse and find it. Net view also does not show the appliance.
If I manually map the share (using the tools, map network drive drop down menu option) I am prompted for the local user login for the appliance. I log in, mapping the resource. The appliance still does not appear in the workgroup list in Windows explorer. (I attempted to refresh windows explorere many times without success)
Eventually after around 10 mins, an "unknown" entry appears in the workgroup, as well as the appliance name itself. After selecting either one, you are prompted for the appliance local user account login. You are once again able to browse the appliance resources from Windows explorer.
|