OpenSolaris

Printable Version Enter a New Search
Bug ID 6647596
Synopsis smp does not enumerate all targets
State 10-Fix Delivered (Fix available in build)
Category:Subcategory driver:smp
Keywords fw-mpt
Responsible Engineer River Li
Reported Against
Duplicate Of
Introduced In solaris_nevada
Commit to Fix snv_82
Fixed In snv_82
Release Fixed solaris_nevada(snv_82) , solaris_10u6(s10u6_02) (Bug ID:2161533)
Related Bugs
Submit Date 7-January-2008
Last Update Date 14-May-2008
Description
Devices that have a REPORT GENERAL payload longer than the SAS 1 standard response cause the IOC to return SAS_SMP_DATA_OVERRUN. This is interpreted as a failure condition, and hence the device is not enumerated.

It is not an error, but the expander wants to return more data than the buffer has allocated.
Work Around
N/A
Comments