OpenSolaris

Printable Version Enter a New Search
Bug ID 6638569
Synopsis raidctl should work with multi pathed drives
State 10-Fix Delivered (Fix available in build)
Category:Subcategory utility:raidcfg-mpt-plugin
Keywords development_escape
Responsible Engineer Jie Cao
Reported Against snv_75 , s10u5_10 , s10u4_12b
Duplicate Of
Introduced In solaris_nevada
Commit to Fix snv_88
Fixed In snv_88
Release Fixed solaris_nevada(snv_88) , solaris_10u6(s10u6_03) (Bug ID:2161203)
Related Bugs 6523832 , 6630279 , 6666306 , 6667944 , 6689977 , 6718423 , 6750443 , 6762299
Submit Date 6-December-2007
Last Update Date 5-June-2008
Description
Please see comments section..
Vendor had adjusted mpt controller's firmware with alternative path info regarding multi-port disk support. The raidctl should handle this info with RAID config actions, otherwise the second path which is not involved in RAID config action will be un-touched, which means an invalid path remains with volume creation, or second path not recovered with volume deleting. Further more, 2 paths from a single disk involved with a volume creation will raise a failure and should be avoided.
Work Around
N/A
Comments
N/A